GLPAcceptedBeyond the letter
UM171 toxicity studies in rats (single dose) and monkeys (three doses) not GLP-compliant
Why: Weight-of-evidence approach; no further questions raised · Weight of evidence
“The single dose toxicity study in rats and the “repeat dose toxicity study” (3x administration with a 7- day washout period) in non-human primates were not in accordance with GLP.”
✓ VerifiedEMA assessment report, p. 45Source ↗ “Based on a 'weight of evidence approach,' it is therefore not deemed relevant to raise questions about this and the submitted discussion is considered sufficient.”
✓ VerifiedEMA assessment report, p. 45Source ↗ GLPAcceptedBeyond the letter
hERG assay with residual UM171 not GLP-compliant
Why: Anticipated residual UM171 level in the product (8 ng/kg) is negligible · Pharmacology or kinetics
“According to ICH S7A and B, safety PD studies such as the hERG assay should be performed in compliance with GLP. However, the study was not GLP compliant.”
✓ VerifiedEMA assessment report, p. 31Source ↗ “However, since the anticipated residual UM171 level in dorocubicel (8 ng/kg for a 70 kg adult) is negligible, the lack of GLP compliance is considered acceptable.”
✓ VerifiedEMA assessment report, p. 31Source ↗ DARTAcceptedBeyond the letter
No reproductive and developmental toxicity studies with UM171 or the cell product
Why: Not recommended in pregnancy; only minimal residual UM171 in the product · Pharmacology or kinetics
“The applicant contended that such studies are unnecessary as ECT-001-CB is not recommended for use in pregnant women, and only minimal residual amounts of UM 171 were detected in dorocubicel. The absence of such studies is considered acceptable.”
✓ VerifiedEMA assessment report, p. 47Source ↗ Efficacy modelCriticised but acceptedBeyond the letter
Manufacturing culture conditions with UM171 not fully substantiated with nonclinical data
Why: No concerns based on submitted clinical data; long-term safety and efficacy followed post-marketing · Human data
“Moreover, adaptations in the production process related to culture of the cells with UM171 have not been fully substantiated with thorough non-clinical data. Based on the submitted clinical data, there are no concerns.”
✓ VerifiedEMA assessment report, p. 48Source ↗ “However, long term safety and efficacy will be followed up in the post-marketing studies.”
✓ VerifiedEMA assessment report, p. 48Source ↗